How to Deal with Abnormal Exhaust Pressure of PSA Nitrogen Generation Equipment?

Oct 30, 2025

Leave a message

Abnormal exhaust pressure of PSA nitrogen generators is a relatively common equipment failure, which can be divided into excessively high pressure or excessively low pressure.

 

When the exhaust pressure of the nitrogen generator is too high, it will have an adverse impact on the normal operation of the equipment, such as causing accelerated wear of molecular sieves.

This situation is mostly caused by failures in some system components.

PSA nitrogen generator

You can consider troubleshooting and handling from the following aspects:

  • Adjust the pressure setting of the equipment to reduce the outlet pressure and reduce the risk of molecular sieve wear.
  • If there is noise during the operation of the equipment, focus on checking the solenoid valve. Adjust or replace the solenoid valve according to the situation.
  • Check whether the one-way valve is leaking and whether the blowback valve is opened too much. Try to replace the one-way valve or its internal sealing ring, or adjust the opening of the blowback valve.
  • Check whether the adsorption pressure is normal. If the adsorption pressure exceeds 0.8Mpa, reduce the inlet pressure; if the adsorption pressure is lower than 0.6Mpa, increase the inlet pressure.

 

If the outlet pressure is too low, it is recommended to troubleshoot the following problems:

PSA nitrogen generator

  • Check whether the filter is clogged, and whether the inlet and outlet pipelines are leaking or blocked.
  • Check whether the safety valve is invalid. If there is any abnormality, replace it in time.
  • Check whether the nitrogen generator's PLC is faulty. If so, repair or replace it.
  • Check whether the adsorption pressure is normal. For the long-term unstable adsorption pressure, consider installing an air storage tank at the inlet to stabilize the pressure.
  • Check whether the performance of the air compressor is abnormal to ensure that the air compressor has sufficient air supply capacity.
  • Check whether there is air cross-talk in the valves of the adsorption dryer and nitrogen analysis unit.

 

It is worth emphasizing that the operation of the equipment must comply with the nitrogen generator's operation manual and safety guidelines. If you are not familiar with these operations, it is recommended to contact professional maintenance personnel or the manufacturer for handling.

 

Get a quote

 

In addition to PSA Nitrogen Generators, we also produce VPSA Oxygen Generators, storage tanks, heat exchangers and other products. If you are interested in PSA Oxygen Systems or other products, please feel free to send an email to sales@gneeheatex.com. We will be very happy to serve you.

 

carbon molecular sieve capacity (KG)

purity/nitrogen capacity (Nm³/h) - Low purity

purity/nitrogen capacity (Nm³/h) - high purity

 

96%

97%

98%

99%

99.95%

99.98%

99.995%

99.999%

120

55

50

45

40

20

15

13

10

150

75

70

65

50

20

20

15

13

180

80

80

70

60

30

22

20

15

210

105

100

90

80

30

25

25

18

240

115

110

100

90

40

30

27

20

275

130

120

110

100

45

35

30

23

300

150

140

130

110

45

40

35

25

336

170

160

140

120

60

45

40

28

360

180

170

150

130

65

48

42

30

420

200

190

170

150

70

55

45

35

444

210

200

180

160

75

50

50

37

480

230

220

200

170

80

60

55

40

516

250

230

210

180

85

65

55

43

540

270

260

230

200

90

70

60

45

600

290

270

240

220

100

75

65

50

624

300

280

250

230

105

80

70

52

660

330

310

280

250

110

85

75

55

720

360

350

320

280

120

90

80

60

840

390

370

330

300

140

100

90

70

900

430

400

360

320

150

110

100

75

960

460

440

410

370

160

120

110

80

1020

480

460

400

350

170

125

115

85

1080

500

470

420

380

180

130

120

90

1200

550

520

470

400

190

140

130

100

1250

630

600

540

480

200

150

140

105

1300

650

650

500

450

220

160

150

110

1350

650

630

570

490

230

170

150

115

1400

670

620

550

500

250

180

160

120

1500

720

680

600

550

260

190

170

130

1550

760

730

650

600

270

200

180

135

1600

770

720

680

580

280

210

190

140

1700

850

800

720

650

300

220

200

150

1800

930

880

780

700

330

240

210

160

1900

950

900

800

730

350

250

220

170

2000

1000

950

850

750

370

270

230

180

2100

1100

1050

950

850

400

280

250

190

2200

1150

1000

900

800

420

300

260

200

2300

1200

1100

1000

900

450

320

270

210