The filter in a PSA Nitrogen Generation System is very important for the entire system. It plays a crucial role in ensuring the cleanliness of compressed air, extending the service life of molecular sieves, improving nitrogen quality, and preventing system failures. Therefore, when selecting and using filters, we should fully consider their performance and quality to ensure the stable operation and long-term benefits of the nitrogen generation system.
To judge the efficiency of a filter, it cannot be done by naked eye observation alone. Professional detection methods, such as particle counters and oil content detectors, are needed for assistance.
The general process is as follows:

- Select Appropriate Detection Equipment:Choose a suitable particle counter or oil content detector based on the parameters to be monitored and the application scenario.
- Prepare Samples:Take samples from before and after the filter in the PSA nitrogen generation system respectively. Ensure that the samples are representative and prevent new contamination from being introduced during the sampling process.
- Measure with Detection Equipment:Put the prepared samples into a particle counter or oil content detector for measurement. Set appropriate test parameters and measurement modes according to the operation instructions of the equipment.For particle counters, parameters such as measurement range and sensitivity usually need to be set. For oil content detectors, it may be necessary to set detection standards and calibration parameters.
- Analyze Measurement Results:After the measurement is completed, record and analyze the measurement results. Compare the changes in the number and size of solid particles and the oil content in the samples before and after the filter.If the number of solid particles and the oil content in the sample after the filter meet the requirements, it indicates that the filter has a good filtering effect.
To ensure the long-term stable operation of the PSA nitrogen generation system, it is necessary to regularly monitor and maintain the filter. Formulating a reasonable maintenance plan and timely replacing failed filter elements or screens can make the system operate more durably and efficiently.
However, if you are still not sure under what circumstances the filter needs to be replaced, you can also refer to the following points:
- Check Usage Records:Understand the usage time and replacement frequency of the filter. Generally speaking, the filter needs to be replaced every 8,000 hours.
- Use a Blockage Indicator:Filters in PSA nitrogen generator systems are usually equipped with blockage indicators, which can prompt the timely replacement of failed filter elements. By observing the status of the indicator, the efficiency of the filter can be indirectly judged.
In addition to PSA Nitrogen Generators, we also produce VPSA Oxygen Generators, storage tanks, heat exchangers and other products. If you are interested in PSA Oxygen Systems or other products, please feel free to send an email to sales@gneeheatex.com. We will be very happy to serve you.
|
Nitrogen production (Nm³/h) |
Effective air consumption (Nm³/min) |
Inlet pipe size (DNmm) |
Outlet pipe diameter (DNmm) |
Host L×W(mm) |
|
5 |
0.7 |
25 |
15 |
1150×600 |
|
10 |
1.4 |
25 |
15 |
1250×880 |
|
20 |
2.8 |
40 |
15 |
1750×1000 |
|
30 |
4.2 |
40 |
25 |
2150×1100 |
|
40 |
5.6 |
50 |
25 |
2250×1140 |
|
50 |
7.0 |
50 |
25 |
2500×1150 |
|
60 |
8.4 |
50 |
25 |
2750×1450 |
|
80 |
11.2 |
65 |
32 |
2750×1450 |
|
100 |
14.0 |
65 |
32 |
2850×1550 |
|
200 |
28.0 |
65 |
32 |
3250×1820 |
|
300 |
42.0 |
80 |
40 |
3500×2150 |